Function:
The C-type salt spray chamber can perform continuous salt spray test or intermittent spray test, can be connected to a computer for remote
operation and control, can record test data and curves, and has a touch screen operation interface.
Major Specifications:
Model | CZ-60C | CZ-90C | CZ-120C | CZ-160C | CZ-200C |
Inner size (WxHxD)(cm) | 60x40x45 | 90x50x60 | 120x50x80 | 160x50x100 | 200x60x120 |
Outer size (WxHxD)(cm) | 110x109x68 | 145x120x88 | 208x133x125 | 247x132x145 | 287x141x165 |
Test lab temperature |
Salt spray test method (NSS ACSS) 35°C ± 1°C; Corrosion resistance test method (CASS) 50℃ ± 1℃ |
||||
Pressure barrel temperature |
Salt spray test method (NSS ACSS) 47°C ± 1°C; Corrosion resistance test method (CASS) 63℃ ± 1℃ |
||||
Test lab capacity | 108L | 270L | 480L | 800L | 1440L |
Salt tank capacity | 15L | 25L | 40L | 40L | 40L |
Salt concentration | Add 0.26g of copper chloride (CuCL2 2H2O) per liter to 5% sodium chloride solution or 5% sodium chloride solution | ||||
Salt spray pressure | 70-170Kpa | ||||
Spray volume | 1~2ml/ (h•80cm2) (collect for at least 16 hours and take the average value) | ||||
Test lab relative humidity | >85% | ||||
PH value | 6.5~7.2 3.0~3.2 | ||||
Spray method | Continuous spray, periodic spray, program spray three modes to choose | ||||
Power | AC220V 1 ∅10A | AC220V 1 ∅20A | AC220V 1 ∅25A |
Product Details
Test Standards:
1)ASTMGB117GB/T2423.17/IEC60068-2-11
2)JIS H8502 GB/T10125-2021/ISO9227:2017
3)GJB150.11A-2009
4)GBT20121-2006/ISO114741998 and other test methods
Inner Box | Details
Reviews
Clear filtersThere are no reviews yet.